This forum will give you access to participate in discussions and attain resources via our vibrant waterjet community . This discussion board is intended for any waterjet user but the majority of the moderators are associates of Flow International Corporation. We will attempt to make this community an unbiased source of information regarding general waterjet topic areas. If you are a registered Flow Waterjet customer and require in-depth product support, please visit FlowParts.com. font>
i have a pressure problem with a cougar2 pump , i can build 40000 psi , when i turn cutting head on pressure drops to 30000 and stays, i have serviced check valves, dynamic bushings, installed new diamond orifice .
I am not familiar with Flow pumps as we use Jet Edge and we also have one Accustream but the theory remains the same. What is the GPM rating of the pump? What size orifice are you using and how many? If you are exceeding the flow capability your pressure will be reduced. Is the pump laboring while running or cycling more rapidly than normal? Is it a single cylinder or dual, if dual are they both activated. We have 8 pumps, 7 of which are run in-line together so as more heads are fired we fire up more pumps to minimize the pressure reduction. Our pumps start up at 55k but typical head pressure is around 50k after travelling through the lines, elbows etc...
Check your incomming water, I'm not sure what the spec's are for your pump but if you arent feeding the pump enough it wont output the volume you need to maintain the 40k either. You may have filter issues on the inlet side.
Please note, the views and recommendations expressed by employees of Flow or it's partners on this website do not necessarily represent those of Flow International Corporation. For more information on this site's Terms of Use , please visit the DXF Copyright and Community Guidelines pages.
Important: Do not upload any DXF's or images without permission unless they consist entirely of content you or your company created.
By clicking "Upload file", you are representing that this DXF or image does not violate the WaterjetGroup.com's forum's Terms of Use and that you own all copyrights to this file or have authorization to upload it.